PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR230
2P-120/240V-30A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
DISCONNECT SWITCH NON-FUSED PULL-OUT
CUTLER HAMMER VECTROL
DPU222R
60A 240V 1PH PULLOUT
240 VAC 1 PHASE; 60 AMPERE; POWER RATING 10 HP; 2 WIRE; NON FUSIBLE FUSE; NEMA 3R; GALVANIZED STEEL ENCLOSURE; SIZE 5.4 INCH W X 3.152 INCH D X 8.7 INCH H; APPROVAL UL

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR2100
2P-120/240V-100A CB
THERMAL MAGNETIC, MAIN; 2 POLE; 208 VAC STAR/120 VAC, 240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
SAFETY SWITCH HUB
CUTLER HAMMER VECTROL
DS200H2
2-IN PLATE TYPE HUB
THREADED HUB; 1 HUB(S); 2 INCH HUB SIZE; USED ON NEMA 3R; SWITCH RATING DOUBLE THROW THROUGH 200 AMPERE

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
METALLIC ENCLOSURE
B-LINE SYSTEMS INC
884SCNK
SCR-CVR W/NO KO
HEIGHT 8 INCH; WIDTH 8 INCH; DEPTH 4 INCH; STEEL; MATERIAL SPECIFICATION 16 GAUGE; ACRYLIC ELECTROCOATED OVER PHOSPHATIZED SURFACE; ANSI 61 GRAY; NEMA 1, IP30; WALL MOUNTING; SCREW ON COVER; APPROVAL UL 50, CSA 22.2; B-LINE[R] BRAND; APPLICABLE STANDARD IEC 529; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 More Details
METALLIC ENCLOSURE
B-LINE SYSTEMS INC
12126SCNK
ENCL W/NO KO
HEIGHT 12 INCH; WIDTH 12 INCH; DEPTH 6 INCH; STEEL; MATERIAL SPECIFICATION 16 GAUGE; ACRYLIC ELECTROCOATED OVER PHOSPHATIZED SURFACE; ANSI 61 GRAY; NEMA 1, IP30; WALL MOUNTING; SCREW ON COVER; APPROVAL UL 50, CSA 22.2; B-LINE[R] BRAND; APPLICABLE STANDARD IEC 529; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR260
2P-120/240V-60A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
METER SOCKET
CUTLER HAMMER VECTROL
MBT48B200BTS
TRLR PNL METR BRKR
RINGLESS; 22 KILOAMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT; SERVICE TYPE OVERHEAD/UNDERGROUND; 120/240 V; 200 AMPERE; NO BYPASS SWITCH; 4 JAW(S); 8 CIRCUIT(S); 4 POLE SPACE(S); NEMA 3R; SURFACE MOUNTING; WIRE SIZE 300 KCMIL; SIZE 14.44 INCH W X 4.94 INCH D X 25.5 INCH H; APPROVAL UL 67, UL 414; INCLUDES MAIN BREAKER, FEED THROUGH LUG; BREAKER FEED TYPE BOTTOM/TOP

Show all:  Residential Meter Socket Circuit Breaker Combinations

 Spec Sheet   |   More Details
METALLIC ENCLOSURE
B-LINE SYSTEMS INC
12124SCNK
ENCL W/NO KO
HEIGHT 12 INCH; WIDTH 12 INCH; DEPTH 4 INCH; STEEL; MATERIAL SPECIFICATION 16 GAUGE; ACRYLIC ELECTROCOATED OVER PHOSPHATIZED SURFACE; ANSI 61 GRAY; NEMA 1, IP30; WALL MOUNTING; SCREW ON COVER; APPROVAL UL 50, CSA 22.2; B-LINE[R] BRAND; APPLICABLE STANDARD IEC 529; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 More Details
METALLIC ENCLOSURE
B-LINE SYSTEMS INC
664SCNK
SCR-CVR W/NO KO
HEIGHT 6 INCH; WIDTH 6 INCH; DEPTH 4 INCH; STEEL; MATERIAL SPECIFICATION 16 GAUGE; ACRYLIC ELECTROCOATED OVER PHOSPHATIZED SURFACE; ANSI 61 GRAY; NEMA 1, IP30; WALL MOUNTING; SCREW ON COVER; APPROVAL UL 50, CSA 22.2; B-LINE[R] BRAND; APPLICABLE STANDARD IEC 529; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 More Details
SCREW COVER WIREWAY END
B-LINE SYSTEMS INC
66E
NEMA1 SC WIREWAY END
SCREW WIREWAY COVER; WIDTH 6 INCH; HEIGHT 6 INCH; (1) (1.25 INCH-1.5 INCH) CONCENTRIC KNOCKOUT(S); STEEL; ANSI 61 GRAY ACRYLIC ELECTROCOATED OVER PHOSPHATIZED SURFACE; NEMA 1, IP30; B-LINE[R] BRAND; 66 MODEL

Show all:  Nema Type 1 Wireway & Fittings

 More Details
LOAD CENTER GROUND BAR KIT
CUTLER HAMMER VECTROL
GBK14
14 CIRCUIT GROUND BAR
LENGTH 5.69 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 14 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR240
2P-120/240V-40A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
MINIATURE BOLT-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BAB1020
20A 1P CKT BRKR
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VDC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING; APPROVAL UL 489, CSA; QUICKLAG[R] BRAND; BAB MODEL

Show all:  Standard Trip Bolt-On Circuit Breakers

 Spec Sheet   |   More Details